Serviceline Industrial Sensors
Phone: 330-486-0001
Fax: 330-405-4710
Serviceline Explosion Protection
Phone: 330-486-0002
Fax: 330-963-5827

Digital Output with Position Feedback FB2216E3

FB2216E3
  • 1-channel
  • 1 digital output, 2 digital inputs
  • Inputs and output Ex ia
  • Installation in suitable enclosures in Zone 1
  • Module can be exchanged under voltage (hot swap)
  • Line fault detection switched on and off
  • Positive or negative logic selectable
  • Simulation mode for service operations (forcing)
  • Permanently self-monitoring
  • Output with watchdog
  • Output with bus-independent safety shutdown input

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Datasheet excerpt: Technical data of  FB2216E3

Slots
Occupied slots1
Supply
Connectionbackplane bus / booster terminals
Rated voltage12 V DC , only in connection with the power supplies FB92**
Power dissipation1.3 W
Power consumption1.85 W
Internal bus
Connectionbackplane bus
Interfacemanufacturer-specific bus to standard com unit
Digital input
Number of channels2
Sensor interface
ConnectionNAMUR sensor
Connection [2]volt-free contact
Connectionchannel I: 2+, 5-; channel II: 3+, 6-
Rated valuesacc. to EN 60947-5-6 (NAMUR)
Switching point/switching hysteresis1.2 ... 2.1 mA / ± 0.2 mA
Internal resistor1 kΩ
Line fault detectioncan be switched on/off for each channel via configuration tool
Connectionmechanical switch with additional resistors (see connection diagram) proximity sensors without additional wiring
Short-circuit< 360 Ω
Open-circuit< 0.35 mA
Minimum pulse duration1 ms
Digital output
Number of channels1
Suitable field devices
Field deviceSolenoid Valve
Field device [2]audible alarm
Field device [3]visual alarm
Connectionchannel I: 1+, 4-
Internal resistor258 Ω
Current limit50 mA
Open loop voltage23 V
Line fault detectioncan be switched on/off for each channel via configuration tool , also when turned off (every 2.5 s the valve is turned on for 2 ms)
Short-circuit< 50 Ω
Open-circuit> 10 kΩ
Response time10 ms (depending on bus cycle time)
Watchdogwithin 0.5 s the device goes in safe state, e.g. after loss of communication
Indicators/settings
LED indicationPower LED (P) green: supply
Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit
Status LED (O: output, I1: input 1, I2: input 2) red: line fault (lead breakage or short circuit) , yellow: state of digital I/O (0/1)
Codingoptional mechanical coding via front socket
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013
Conformity
Electromagnetic compatibilityNE 21
Degree of protectionIEC 60529
Environmental testEN 60068-2-14
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6
Damaging gasEN 60068-2-42
Relative humidityEN 60068-2-78
Ambient conditions
Ambient temperature-40 ... 60 °C (-40 ... 140 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity95 % non-condensing
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Vibration resistancefrequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles
frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Mechanical specifications
Degree of protectionIP20 (module) , a separate housing is required acc. to the system description
Connectionremovable front connector with screw flange (accessory)
wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2)
Massapprox. 750 g
Dimensions28 x 107 x 132 mm (1.1 x 4.2 x 5.2 inch)
Data for application in connection with hazardous areas
EU-type examination certificatePresafe 19 ATEX 14054U
MarkingEx-Hexagon II 2(1)G Ex db eb q [ia Ga] IIC Gb
II (1)D [Ex ia Da] IIIC
I (M1) [Ex ia Ma] I
Input
Voltage10 V
Current13 mA
Power33 mW (linear characteristic)
Internal capacitance1.2 nF
Internal inductance0 mH
Output
Voltage24.2 V
Current108 mA
Power654 mW
Internal capacitance12 nF
Internal inductance0 mH
Galvanic isolation
Input/power supply, internal bussafe electrical isolation acc. to EN 60079-11, voltage peak value 375 V
Output/power supply, internal bussafe electrical isolation acc. to EN 60079-11, voltage peak value 375 V
Directive conformity
Directive 2014/34/EUEN 60079-0:2018+AC:2020
EN 60079-1:2014
EN 60079-5:2015
EN 60079-7:2015+A1:2018
EN 60079-11:2012
International approvals
ATEX approvalPresafe 19 ATEX 14054U
IECEx approvalIECEx PRE 19.0009U
Approved forEx db eb q [ia Ga] IIC Gb
[Ex ia Da] IIIC
[Ex ia Ma] I
General information
System informationThe module has to be mounted in appropriate backplanes and housings (FB92**) in Zone 1, 2, 21, 22 or outside hazardous areas (gas or dust). Here, observe the corresponding EC-type examination certificate.
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

Classifications

SystemClasscode
ECLASS 13.027210101
ECLASS 12.027210101
ECLASS 11.027210101
ECLASS 10.0.127210101
ECLASS 9.027210101
ECLASS 8.027210101
ECLASS 5.127210120
ETIM 9.0EC001485
ETIM 8.0EC001485
ETIM 7.0EC001485
ETIM 6.0EC001485
ETIM 5.0EC001485
UNSPSC 12.139121008

Details: FB2216E3

The digital output features 1 output with 2 feedback inputs.

The device can be used to switch solenoids, sounders, or indicators (without line fault detection) in the field. Furthermore, the device accepts digital input signals of NAMUR sensors or mechanical contacts from the field.

The output can be switched off via a contact. This can be used for bus-independent safety applications.

Open and short circuit line faults are detected in on and off state.

The intrinsically safe inputs and the output are galvanically isolated from the bus and the power supply.

Datasheet: FB2216E3

DatasheetFile TypeFile Size
Datasheet FB2216E3PDF1147 KB
Datenblatt FB2216E3PDF1147 KB

Documents: FB2216E3

ManualsFile TypeFile Size
FB Hardware ManualPDF9157 KB
FB-Hardware-HandbuchPDF9182 KB
Instruction manuals
ИнструкцииPDF186 KB
Instruction manual / BetriebsanleitungPDF363 KB
Návod k poużitíPDF180 KB
Instruktions manualPDF179 KB
Instruction manualPDF189 KB
KasutusjuhendPDF174 KB
KäyttöohjePDF173 KB
Manuel d'instructionsPDF185 KB
BetriebsanleitungPDF186 KB
Οδηγίες χρήσηςPDF191 KB
HandleidingPDF181 KB
Instruction manual / BetriebsanleitungPDF179 KB
Használati útmutatóPDF181 KB
Manuale di istruzioniPDF181 KB
Lietošanas pamācībaPDF178 KB
Instrukciju vadovasPDF179 KB
Instrukcja obsługiPDF182 KB
Manual de instruçõesPDF182 KB
Manual de utilizarePDF181 KB
Návod na poużitiePDF180 KB
Navodila za uporaboPDF178 KB
Manual de instruccionesPDF183 KB
ManualPDF176 KB
Application reports
Application Report - Communication Redundancy for Uninterrupted OperationPDF529 KB
Application Report - LB and FB Remote I/O Systems for Digitally Connecting Analog Field DevicesPDF208 KB
Application Report - Space Saving Extension for Existing PlantsPDF300 KB
Application Report - Using Remote I/O Systems for the Efficient Digitalization of PlantsPDF371 KB
Applikationsbericht - Platzsparende Erweiterung für bestehende AnlagenPDF300 KB
Applikationsbericht - Redundanz der Kommunikation für ungestörten BetriebPDF530 KB
Applikationsbericht - Remote-I/O-Systeme Typ LB und FB für digitale Anbindung analoger FeldgerätePDF208 KB
Applikationsbericht - Remote-I/O-Systeme für effiziente AnlagendigitalisierungPDF365 KB
Documents
Functional Safety ManualPDF2422 KB
Selection table - Solenoid driver/valve combinationsPDF299 KB
Supported I/O modulesPDF31 KB
Auswahltabelle - Kombination Ventil - SteuerbausteinPDF300 KB
Handbuch funktionale SicherheitPDF2435 KB
Unterstützte E/A-ModulePDF34 KB

CAD+CAE: FB2216E3

CADFile TypeFile Size
CAD 3-D / CAD 3-DSTP4752 KB
CAD Portal / CAD PortalLINK---
EPLAN
CAE EPLAN Data Portal / CAE EPLAN Data PortalLINK---
EPLAN macro EDZ / EPLAN Makro EDZEDZ853 KB

Approvals+Certificates: FB2216E3

CertificatesFile TypeFile Size
Brasil TUV Rheinland BrazilPDF1201 KB
China NEPSIPDF3326 KB
China SITIIAS CCC Ex CertificatePDF2172 KB
Europe Presafe DNV GL ATEX Category (1) D ATEX Category 2 (1) ATEX Category (M1)PDF257 KB
Presafe DNV GL IECEx Certificate of ConformityLINK---
United Kingdom CML UK-Type Examination Certificate UKEX Category (1) D UKEX Category (1) G UKEX Category (M1)PDF180 KB
Declaration of Conformity
EU Declaration of Conformity (P+F)PDF1148 KB
EU Declaration of Conformity (P+F)PDF1141 KB
EU Declaration of Conformity (P+F)PDF1140 KB
EU Declaration of Conformity (P+F)PDF1142 KB
UK Declaration of Conformity (P+F)PDF1110 KB
EU Declaration of Conformity (P+F)PDF1139 KB
EU Declaration of Conformity (P+F)PDF1140 KB
EU Declaration of Conformity (P+F)PDF1140 KB
EU-Konformitäterklärung (P+F)PDF1142 KB
EU Declaration of Conformity (P+F)PDF1148 KB
EU Declaration of Conformity (P+F)PDF1139 KB
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)PDF1140 KB
EU Declaration of Conformity (P+F)PDF1141 KB
EU Declaration of Conformity (P+F)PDF1139 KB
EU Declaration of Conformity (P+F)PDF1140 KB
EU Declaration of Conformity (P+F)PDF1141 KB
EU Declaration of Conformity (P+F)PDF1143 KB
EU Declaration of Conformity (P+F)PDF1141 KB
EU Declaration of Conformity (P+F)PDF1140 KB
EU Declaration of Conformity (P+F)PDF1142 KB
EU Declaration of Conformity (P+F)PDF1139 KB
EU Declaration of Conformity (P+F)PDF1139 KB
EU Declaration of Conformity (P+F)PDF1139 KB
EU Declaration of Conformity (P+F)PDF1141 KB