Inductive positioning system PMI120-F90-IU2EP-IO-V15-3G-3D

PMI120-F90-IU2EP-IO-V15-3G-3D
  • Parameterization and diagnosis via IO-Link
  • Measuring range 0 ... 120 mm
  • Parameterisable measuring range
  • Analog current or voltage output, programmable
  • 2 Push-pull outputs
  • Switch points programmable via IO-Link

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Datasheet excerpt: Technical data of  PMI120-F90-IU2EP-IO-V15-3G-3D

General specifications
Switching element functionAnalog current or voltage output, programmable
2 switch outputs, programmable
Object distance0.5 ... 3 mm , recommended: 1.5 mm
Measurement range0 ... 120 mm
Linearity range1 ... 119 mm
Nominal ratings
Operating voltage12 ... 30 V DC
(13 ... 30 V when analog voltage output is parameterized)
Reverse polarity protectionreverse polarity protected
Linearity errorwithin measuring range: ± 0.8 mm
within linearity range: ± 0.4 mm
Repeat accuracy± 0.1 mm
Resolution50 µm
Temperature drift± 0.5 mm (-25 °C ... 70 °C)
No-load supply current≤ 40 mA
Operating voltage indicatorLED green
Functional safety related parameters
MTTFd278 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Indicators/operating means
LED S1switching state Switching output 1
LED S2switching state Switching output 2
LED S3Damping element in the configured analog measuring range
LED STATUSStatus display LED, green/red (Power on, communication/error, missing damping element)
Interface
Interface typeIO-Link (via C/Q = Pin 4)
IO-Link revision1.1
Device profileSmart Sensor
Device ID0x200404 (2098180)
Transfer rateCOM2 (38.4 kBit/s)
Value range0000h ... 9600h
Min. cycle time2.3 ms
Process data widthProcess data input: 16 Bit
Process data output: none
SIO mode supportyes
Compatible master port typeA
Switching output
Output type2 push-pull outputs (can be parameterized), short-circuit-proof, reverse polarity protection, surge-proof
Operating current≤ 100 mA / Output
Switching window± 1 mm
Switching hysteresis0.2 mm
Voltage drop≤ 3 V
Short-circuit protectionpulsing
Analog output
Output type1 current output: 4 ... 20 mA or 1 voltage output: 0 ... 10 V , programmable
Load resistorcurrent output: ≤ 400 Ω
voltage output: ≥ 1000 Ω
Short-circuit protectionvoltage output: current limit
Compliance with standards and directives
Standard conformity
StandardsEN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
EN 60947-5-7:2003
EN61131-9:2013
IEC 60947-5-7:2003
IEC 61131-9:2013
Approvals and certificates
IECEx approval
Equipment protection level Gc (ec)IECEx TUR 21.0019X
Equipment protection level Dc (tc)IECEx TUR 21.0020X
ATEX approval
Equipment protection level Gc (ec)TÜV 20 ATEX 8525 X
Equipment protection level Dc (tc)TÜV 20 ATEX 8526 X
UL approvalcULus Listed, Class 2 Power Source, Type 1 enclosure
Marine approvalDNVGL TAA00001V2
Ambient conditions
Ambient temperature-25 ... 85 °C (-13 ... 185 °F)
Mechanical specifications
Connection type5-pin, M12 x 1 connector
Degree of protectionIP67 / IP69K
Material
HousingPBT, stainless steel 1.4571 , brass, nickel-plated
Targetmild steel, e. g. 1.0037, SR235JR (formerly St37-2)
Mass113 g
Dimensions
Height40 mm
Width23 mm
Length135.2 mm
General information
Use in the hazardous areasee instruction manuals

Classifications

SystemClasscode
ECLASS 13.027274004
ECLASS 12.027274004
ECLASS 11.027270702
ECLASS 10.0.127270702
ECLASS 9.027270702
ECLASS 8.027270702
ECLASS 5.127270702
ETIM 9.0EC001852
ETIM 8.0EC001852
ETIM 7.0EC001852
ETIM 6.0EC001852
ETIM 5.0EC001852
UNSPSC 12.139121550

Details: PMI120-F90-IU2EP-IO-V15-3G-3D

Datasheet: PMI120-F90-IU2EP-IO-V15-3G-3D

DatasheetFile TypeFile Size
Datasheet PMI120-F90-IU2EP-IO-V15-3G-3DPDF1161 KB
Fiche de données PMI120-F90-IU2EP-IO-V15-3G-3DPDF1187 KB
Datenblatt PMI120-F90-IU2EP-IO-V15-3G-3DPDF1166 KB
Hoja de datos PMI120-F90-IU2EP-IO-V15-3G-3DPDF1199 KB

Documents: PMI120-F90-IU2EP-IO-V15-3G-3D

BrochuresFile TypeFile Size
Installation and user instructions for offline parameterization of IO-Link sensorsPDF1788 KB
Installations-/Benutzeranweisungen für die Offline-Parametrierung von IO-Link-SensorenPDF1764 KB
Manuals
Manual PMIxxx-F90-...-IO-... Inductive Positioning Measurement System with IO-LinkPDF2695 KB
Handbuch PMIxxx-F90-...-IO-... Induktives Positionsmesssystem mit IO-LinkPDF3537 KB
Instruction manuals
ИнструкцииPDF183 KB
Návod k poużitíPDF175 KB
Instruktions manualPDF173 KB
Instruction manualPDF175 KB
KasutusjuhendPDF169 KB
KäyttöohjePDF168 KB
Manuel d'instructionsPDF178 KB
BetriebsanleitungPDF175 KB
Οδηγίες χρήσηςPDF187 KB
HandleidingPDF174 KB
Instruction manual / BetriebsanleitungPDF173 KB
Használati útmutatóPDF177 KB
Manuale di istruzioniPDF174 KB
Lietošanas pamācībaPDF174 KB
Instrukciju vadovasPDF175 KB
Instrukcja obsługiPDF177 KB
Manual de instruçõesPDF177 KB
Manual de utilizarePDF176 KB
Návod na poużitiePDF175 KB
Navodila za uporaboPDF173 KB
Manual de instruccionesPDF177 KB
ManualPDF172 KB
Technical information
Installation and Design Notes for Position Sensors, F90 SeriesPDF311 KB
Montage- und Konstruktionshinweise für Positionssensoren, Serie F90PDF320 KB
Application reports
Application Report - Precise Dancer Control in Battery Cell ManufacturingPDF144 KB
Application Report - Reliable Detection in the Production of Motor Chain TensionersPDF186 KB
Applikationsbericht - Präzise Tänzersteuerung in der BatteriezellenfertigungPDF145 KB
Applikationsbericht - Zuverlässige Detektion in der Herstellung von MotorkettenspannernPDF198 KB
Documents
Brief instructionsPDF566 KB

CAD+CAE: PMI120-F90-IU2EP-IO-V15-3G-3D

CADFile TypeFile Size
CAD 3-D / CAD 3-DSTP706 KB
CAD Portal / CAD PortalLINK---

Approvals+Certificates: PMI120-F90-IU2EP-IO-V15-3G-3D

CertificatesFile TypeFile Size
- DNV MarinePDF385 KB
Canada USA UL Ordinary LocationPDF546 KB
Europe TUV Rheinland ATEX ec 3GPDF524 KB
Europe TUV Rheinland ATEX tc 3DPDF2307 KB
IO-Link Manufacturer DeclarationPDF244 KB
Worldwide TUV Rheinland IECEx ecLINK---
Worldwide TUV Rheinland IECEx tcLINK---
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)PDF1220 KB
UK Declaration of Conformity (P+F)PDF1217 KB

Associated Products: PMI120-F90-IU2EP-IO-V15-3G-3D

Accessories
22.00  USD
Netlist price. Your individual price will be calculated during checkout.

In stock

Damping element for sensors of type F90, F112, and F166; side holefa
Mounting bracket for mounting of F90 sensorsfa
682.00  USD
Netlist price. Your individual price will be calculated during checkout.

In stock

EtherNet/IP IO-Link master with 8 inputs/outputs, DIN rail, screw terminalfa
682.00  USD
Netlist price. Your individual price will be calculated during checkout.

In stock

PROFINET IO IO-Link master with 8 inputs/outputs, DIN rail, push-in terminalsfa
682.00  USD
Netlist price. Your individual price will be calculated during checkout.

In stock

PROFINET IO IO-Link master with 8 inputs/outputs, DIN rail, screw terminalfa
420.00  USD
Netlist price. Your individual price will be calculated during checkout.

In stock

IO-Link master, supply via USB port or separate power supply, LED indicators, M12 plug for sensor connectionfa
682.00  USD
Netlist price. Your individual price will be calculated during checkout.

In stock

EtherNet/IP IO-Link master with 8 inputs/outputs, DIN rail, push-in connectorsfa